EFKA AB220A/320A FP220A/320A
85
Supplier Level
Code no. 311 with control operation
Code no. 3112 with control panel operation
Parameter Designation Unit max min Preset Ind.
325 cti Erasing all TEACH IN data A/A/A/A
- Input code number 3112 after power On
- Press the E key
- Input parameter 325
- Press the E key
- Input 3112
- Press the P key
- The display briefly shows “deleted“, and a short
acoustic signal is issued
- Press the P key - all TEACH IN programs have
been erased!
330 kA1 Coupled signal A1 and sewing foot lifting or backtacking 3 0 0 F/F/F/E
0 = Coupling off
1 = Coupling with sewing foot lifting
2 = Coupling with backtacking
3 = Coupling with sewing foot lifting and backtacking
335 kA2 Coupled signal A2 and sewing foot lifting or backtacking 3 0 0 F/F/F/E
0 = Coupling off
1 = Coupling with sewing foot lifting
2 = Coupling with backtacking
3 = Coupling with sewing foot lifting and backtacking
401 EEP Immediate storage of all changed data 1 0 0 A/A/A/A
- Input code number 3112 after power On
- Press the E key
- Input parameter 401
- Press the E key
- Set display from 0 to 1
- Press the E or P key
- All data are stored
500 Sir Recall of Fast Installation Routine (SIR)
(see description on page 8!)