Duerkopp Adler HP Series Additional guide Manual de usuario Pagina 74

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 88
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 73
EFKA AB220A/320A FP220A/320A
74
Supplier Level
Code no. 311 with control operation
Code no. 3112 with control panel operation
Parameter Designation Unit max min Preset Ind.
234 PdO New start after machine run blockage 1 0 1 A/A/A/A
0 = New start after disabling machine run
blockage without influence by the pedal
(e. g. with automats)
1 = New start after disabling machine run
blockage only if pedal in pos. 0
235 bkS Braking curve in the overlock mode On/Off 1 0 0 A/A/A/A
0 = Braking curve Off
1 = Braking curve On for precise stop upon chain
suction at the seam end
236 FLP 0 = Sewing foot lift possible in all positions 2 0 0 A/A/A/A
1 = Sewing foot lift possible in position 2
2 = Sewing foot lift at the seam end stored with pedal
backward. Storing undone with pedal slightly forward.
237 tkS Switch-off delay for chain suction at the ms 2550 **) 0 0 A/A/A/A
seam end, if parameter 022 = 2.
238 EnP Software debouncing for all inputs: 1 0 1 A/A/A/A
0 = No debouncing
1 = With debouncing
239 FEL Selection of the input function on socket B18/5 66 0 0 F/F/F/E
0 = Light barrier function, if 009 = 1
All other functions as with parameter 240.
240 in1 Selection of the input functions on socket ST2/7 66 0 0 *) F/F/F/E
for input 1
0 = No function
1 = Needle up/down
2 = Needle up
3 = Single stitch (basting stitch)
4 = Full stitch
5 = Needle to position 2
6 = Machine run blockage effective with open
contact
7 = Machine run blockage effective with closed
contact
8 = Machine run blockage unpositioned effective
with open contact
9 = Machine run blockage unpositioned effective
with closed contact
10 = Automatic speed n12 without pedal
11 = Limited speed n12 pedal controlled
(see parameter 266)
12 = Sewing foot lifting with pedal in position 0
(neutral)
13 = High lift for walking foot with speed limitation n10
(operational mode not stored)
14 = High lift for walking foot (flip-flop 1) with speed
limitation n10
15 = Tape cutter / fast scissors, function only in
chainstitch and overlock mode
16 = Intermediate backtack / intermediate stitch
condensing
17 = Stitch regulator suppression / recall
18 = Unlocking the chain, can be activated by
keystroke, but will be executed only at the
seam end
19 = Reset bobbin thread monitor if parameter
030 = >0
20 = Handwheel running in the direction of rotation
according to the setting of parameter 161
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.
Vista de pagina 73
1 2 ... 69 70 71 72 73 74 75 76 77 78 79 ... 87 88

Comentarios a estos manuales

Sin comentarios