Duerkopp Adler HP Series Additional guide Manual de usuario Pagina 12

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 88
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 11
EFKA AB220A/320A FP220A/320A
12
Connection of a HSM001 Hall sensor module Connection of a LSM002 light barrier module
or an IPG001 pulse encoder
Adapter cord 1113229 in case of multiple assignment of socket B18!
POS2 OUT - Output for position 2
POS IN - Input for positions
G1/G2 OUT - Output of generator impulses
TXD/RXD - Serial transmission lines
LSM IN - Possibility of connecting a light barrier module to socket B18/8
(If parameter 239 = 0, the light barrier function is selected.
Identification of the signal when switched to 0V.)
LSM002 - Reflection light barrier module
HSM... - Hall sensor module
IPG... - Pulse encoder
If parameter 239 is set to >0, it is possible to operate a key at the input of the B18/8 connector.
There is a supply voltage of +5V for external devices on the B18/4 socket. After opening the cover, this voltage can be
changed to +15V by replugging a multipole connector J1 on the printed circuit board.
+5V = Connect lefthand pins 1 and 2 with jumper
(factory setting)
+15V = Connect righthand pins 3 and 4 with jumper
1) Nominal voltage +15V, 100mA (repluggable to +5V, 100mA)
2) Transistor output with open collector max. 40V, 10mA
*) Front view of the socket (component side) and/or rear view of the plug (soldering side)
A
TTENTION!
Before opening the cover, turn power off!
B80
B18
B2
J4
31
+5V
42
J4
1 3
4
+15V
2
KL2351
J4
Vista de pagina 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 87 88

Comentarios a estos manuales

Sin comentarios