EFKA AB220A/320A FP220A/320A
39
Mode 4, 5, 6 or 7 (function “unlocking the chain” with light barrier)
FL
t3
30
(MST)
(ML)
ST2/32
ST2/34
ST2/35
ST2/
LS
ENTK
M6
M5
STV
ST2/21
ST2/20
POS.1
POS.2
-
+
n
1
-2
-1
0
2/1
LS
n2 n5
5430 76
t5t4
n1
drd
n1
ird
0256/ ENTK- 1
Mark Function Parameter Control V810 V820
FAm Mode 5 290 = 5
drE Direction of motor rotation Clockwise 161 = 0
Frd Reverse motor rotation 182 = 1
Basic position 2 On S5 key 4 key 7 key
End stitch condensing and thread trimmer *) On
LS Light barrier 009 = ON
mEk Unlock the chain automatically with light barrier 190 = 2
in7 Machine run blockage effective with open contact 246 = 6
in8 Automatic speed n12 without pedal 247 = 10
in.. Assign the function “unlocking the chain” to an output 2..
n1 Positioning speed 110
n2 Maximum speed 111
n5 Speed after light barrier sensing 114
LS Light barrier compensating stitches 004
ird Number of reversing increments 180
drd Switch-on delay of reverse motor rotation 181
t3 Start delay from lifted sewing foot 202
t4 Full power of sewing foot lifting 203
t5 Pulsing of sewing foot lifting 204
tGn Speed gate damping period 222
dGF Speed gate 2 224 = 1
kdF Switch-on delay of sewing foot lifting 288
*) When unlocking the chain, the functions “stitch condensing” and “thread trimmer” are suppressed!