Duerkopp Adler HP Series Additional guide Manual de usuario Pagina 42

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 88
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 41
EFKA AB220A/320A FP220A/320A
42
Mode 7 (overlock) parameter 232 = 0 (tape cutter) / parameter 018 = 0 (seam end with stop)
ST2/32
ST2/30
M5
LS
M6
(ML)
(MST)
ckL
ST2/20
ST2/36
ST2/34
POS.2
ST2/35
ST2/21
ST2/37
ST2/28
ST2/27
M4
M1
M2
M3
FL
KS
(FSPL)
(AH)
KLM
t3
POS.1
-
/21
n
+
-2
-1
0
1
<
<
SFS
ckL
kt3
c3
SFS
c1
c1
c3
n3
0 4321 5 6 7 8
n2 n1
0256/ MODE- 7a
LSt3
kt3c4
c2c4
<
c2
53 41
n2 n5
71 2 3 4 5 6
n4
KLM
kt2
kt1kd1
kd2
kdF t4 t5
n7
Mark Function Parameter Control V810 V820
FAm Mode 7 290 = 7
Counts c1, c2, c3 and c4 On S2/3 key 1/2 key 1/4 key
Sewing foot lifting at the seam end On S4 key 3 key 6 key
LS Light barrier 009 = 1
UoS Sequence “overlock mode with stop” 018 = 0
-Pd Function “pedal in pos. –2” blocked 019 = 2
kLm Clamp at the seam end On 020 = 1
SPO Chain suction at the seam end until pedal in pos. 0 022 = 1
tFS Beginning of thread tension release at the start of the 025 = 0
seam
LSS Start blockage with light barrier uncovered 132 = 0
kSA Stitch counting at the start of the seam at fixed 143 = 0
speed n3
kSE Stitch counting at the seam end at fixed speed n4 144 = 0
mhE Seam end after count c2 191 = 1
PLS Speed n5 after light barrier sensing 192 = 0
kSL Chain suction On after light barrier compensating 193 = 0
stitches
USS Tape cutter function 232 = 0
n1 Positioning speed 110
n2 Maximum speed 111
n3 Speed for start counting 112
n4 Speed for end counting 113
n5 Speed after light barrier sensing 114
n7 Trimming speed 116
c2 End counting for chain suction 000
c1 Start counting for chain suction 001
c3 Start counting for tape cutter 002
c4 End counting for tape cutter 003
LS Light barrier compensating stitches 004
ckL Run-out stitches clamp at the start of the seam 021
SFS Stitches from light barrier uncovered until end of 157
thread tension release (M4)
kd1/kd2 Delay times of outputs M1/M2 280/282
kt1/kt2 ON periods of outputs M1/M2 281/283
kt3 ON period of tape cutter 285
kdF Switch-on delay of sewing foot lifting 288
Vista de pagina 41