EFKA AB220A/320A FP220A/320A
77
Supplier Level
Code no. 311 with control operation
Code no. 3112 with control panel operation
Parameter Designation Unit max min Preset Ind.
263 ihP 0 = Signal “high lift for walking foot” (M6), when key is 1 0 0 A/A/A/A
closed.
1 = Signal “high lift for walking foot” (M6), when key is
open.
(Function only if parameter 137 = 1)
264 iS1 0 = Signal “manual stacker” (M7), when key is closed. 1 0 0 A/A/A/A
1 = Signal “manual stacker” (M7), when key is open.
(Function in all modes except mode 16)
265 ktS ON period of manual stacker (M7) ms 2550 **) 0 500 A/A/A/A
266 inr 0 = Limited speed n12 pedal controlled, when key is 1 0 0 A/A/A/A
closed.
1 = Limited speed n12 pedal controlled, when key is
open.
(Function if parameters 240...249 = 11)
269 PSv Positioning shift degrees 100 0 15 *) A/A/A/A
270 PGm Connection of a sensor e. g. light barrier sensor to 5 0 0 *) A/A/A/A
light barrier socket B18/7. Selection of the desired
function!
0 = The positions are generated by means of the
transmitter incorporated in the motor and can be set
by means of parameter 171.
1 = Setting the sensor to position 2.
Set position 1 using parameter 271, starting from
leading edge position 2.
2 = Setting the sensor to position 2.
Set position 1 using parameter 271, starting from
trailing edge position 2.
3 = Setting the sensor to position 1.
Set position 2 using parameter 271, starting from
leading edge position 1.
4 = Setting the sensor to position 1.
Set position 2 using parameter 271, starting from
trailing edge position 1.
5 = No position sensor available. The drive stops
unpositioned. The thread trimmer function is
suppressed with this setting.
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.
= 0V
OUT
OUT
OUT
OUT
ST2
IN
POS1
ST2/21
POS2
POS2
ST2/20
POS1
ST2/21
ST2/20
POS2
ST2/21
POS1
ST2/20
POS1
ST2/20
POS
B18/7
ST2/21
POS2
SEN
= high
0256/ SEN- 1
Pa 271
Pa 271
Pa 271
Pa 271
360°
270 = 1270 = 3270 = 4 270 = 2
+5V
0V