Duerkopp Adler HP Series Additional guide Manual de usuario Pagina 62

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 88
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 61
EFKA AB220A/320A FP220A/320A
62
Mode 25 (lockstitch Juki LU2210/LU2260)
n10
5
ST2/27
ST2/6
ST2/31
ST2/32
ST2/30
M11
in3
M5
M6
(HP)
(LHP)
(ML)
(HP)
0
n
ST2/20
POS.1
POS.2
ST2/35
ST2/21
ST2/37
ST2/34
ST2/28
VR
M1
M2
M3
FL
(FSPL)
(FA)
(FW)
t3
-
0
-1
-2
/
1
21
+
n3 n2
c2 c1
1 2 3 1 2 3
t1
1 2 3 4
cHP
0256/ MODE- 25
tFA
3
n7n2 n4
6
7
tHP
c4c3
0 1 2 1 2
n7
iFA
FSE FSA
t6
t7
Mark Function Parameter Control V810 V820
FAm Mode 25 290 = 25
Double start backtack On S2 key 1 key 1 key
Double end backtack On S3 key 2 key 4 key
Pot External potentiometer is active 126 = 3
hP High lift for walking foot 137 = 1
in3 High lift for walking foot with speed limitation n10 242 = 14
PGm Setting an external sensor to position 1 270 = 3
(A sensor must be connected!)
n2 Maximum speed 111
n3 Start backtack speed 112
n4 End backtack speed 113
n7 Trimming speed 116
n10 High lift walking speed 117
c2 Start backtack stitches forward 000
c1 Start backtack stitches backward 001
c3 End backtack stitches backward 002
c4 End backtack stitches forward 003
tHP High lift walking speed run-out time 152
cHP Stitch counting high lift for walking foot 185
t1 Delay until speed release after start backtack 200
t3 Start delay from lifted sewing foot 202
t6 Thread wiper ON period 205
t7 Sewing foot switch-on delay after thread wiper 206
iFA Activation angle of the thread trimmer 250
FSA Thread tension release ON period 251
FSE Thread tension release delay depending on angle 252
tFA Stop time for thread trimmer 253
Vista de pagina 61