EFKA AB220A/320A FP220A/320A
78
Supplier Level
Code no. 311 with control operation
Code no. 3112 with control panel operation
Parameter Designation Unit max min Preset Ind.
270 PGm Connection of a sensor e. g. light barrier sensor to 5 0 0 *) A/A/A/A
light barrier socket B18/7. Selection of the desired
function!
0 = Function as in table on previous page!
1 = Setting the sensor to position 2.
Set position 1 using parameter 271, starting from
trailing edge position 2.
2 = Setting the sensor to position 2.
Set position 1 using parameter 271, starting from
leading edge position 2.
3 = Setting the sensor to position 1.
Set position 2 using parameter 271, starting from
trailing edge position 1.
4 = Setting the sensor to position 1.
Set position 2 using parameter 271, starting from
leading edge position 1.
5 = Function as in table on previous page!
= 0V
OUT
OUT
OUT
OUT
ST2
IN
POS1
POS2
ST2/21
POS1
ST2/20
POS2
ST2/21
ST2/20
POS2
ST2/21
POS1
ST2/20
ST2/20
POS1
POS
B18/7
POS2
ST2/21
SEN
= high
0256/ SEN- 2
Pa 271
Pa 271
Pa 271
Pa 271
360°
270 = 1270 = 3270 = 4 270 = 2
+5V
0V
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
Parameter Designation Unit max min Preset Ind.
271 PGr Number of angular degrees after the sensor degrees 255 0 180 *) A/A/A/A
position on the machine handwheel
272 trr Transmission ratio between motor shaft and machine 255 015 100 *) A/A/A/A
shaft (calculation formula see instruction manual!)
The transmission ratio should be determined and
indicated as precisely as possible!
273 ASi Signals M8, M9, M10 On/Off 1 0 0 A/A/A/A
(0 = Off, 1 = On)
274 Ad1 Delay time of signal M8 at the start of the seam ms 2550 **) 0 40 *) A/A/A/A
275 At1 ON period of signal M8 at the start of the seam ms 2550 **) 0 150 *) A/A/A/A
276 Ad2 Delay time of signal M9 at the start of the seam ms 2550 **) 0 50 A/A/A/A
277 At2 ON period of signal M9 at the start of the seam ms 2550 **) 0 60 A/A/A/A
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.