EFKA AB220A/320A FP220A/320A
80
Supplier Level
Code no. 311 with control operation
Code no. 3112 with control panel operation
Parameter Designation Unit max min Preset Ind.
20 = Lockstitch mode: Juki (LU1510-7 /DNU1541-7)
»Slide-in strip for V810 and V820 = 1«
21 = Chainstitch mode with stitch lock:
Yamato (VG2730-156M)
»Slide-in strip for V810 = 5«
»Slide-in strip for V820 = 3«
22 = Lockstitch mode: Brother (B-891)
»Slide-in strip for V810 and V820 = 1«
23 = Lockstitch mode: Dürkopp Adler (271...275)
»Slide-in strip for V810 and V820 = 1«
24 = Chainstitch mode: Pegasus (MHG-100)
25 = Lockstitch mode: Juki (LU2210/LU2260)
»Slide-in strip for V810 and V820 = 1«
26 = Lockstitch mode: Jentschmann
»Slide-in strip for V810 and V820 = 1«
Modes 1, 11, 12, 18, 19 are selectable, but their
functions correspond to mode 0!
Note
When selecting the trimming mode by means of parameter 290, the connected V810 or V820 control panel is
automatically sensed and the corresponding slide-in strip number is selected by means of parameter 291 and 292,
respectively. Should a different strip be inserted, its number can be set by means of parameter 291 and 292, respectively,
after having selected the trimming mode.
Parameter Designation Unit max min Preset Ind.
291 810 Select slide-in strip number for the V810 control 8 0 5 *) A/A/A/A
panel (illustration see chapter “Slide-in Strips for the
V810/V820 Control Panels)
292 820 Select slide-in strip number for the V820 control 10 0 3 *) A/A/A/A
panel (illustration see chapter “Slide-in Strips for the
V810/V820 Control Panels)
293 tF1 Selection of the input function by means of the 19 0 17 *) A/A/A/A
(A) key “F1” on the V810/V820 control panel
0 = No function
1 = Needle up/down
2 = Needle up
3 = Single stitch (basting stitch)
4 = Full stitch
5 = Needle to position 2
6...12 = No function
13 = High lift for walking foot with speed limitation
n10 (operational mode not stored)
14 = High lift for walking foot with speed limitation
n10 (operational mode stored)
15 = Tape cutter / fast scissors
(in chainstitch and overlock mode)
16 = Intermediate backtack/intermediate stitch
condensing
17 = Stitch regulator suppression / recall
18 = No function
19 = Reset bobbin thread monitor if parameter
030 = >0
294 tF2 Selection of the input function by means of the 19 0 1 *) A/A/A/A
(B) key “F2” on the V810/V820 control panel
Functions of the key as with parameter 293
295 nAM Switch proximity switches for inputs in2, in7, in8, in9 1 0 0 A/A/A/A
*) Depending on the selected mode. See table at the beginning of the List of Parameters!