EFKA AB220A/320A FP220A/320A
82
Supplier Level
Code no. 311 with control operation
Code no. 3112 with control panel operation
Parameter Designation Unit max min Preset Ind.
302 tr1 Starting point for signal A1 4 0 0 A/A/A/A
0 = Start at the beginning of the seam
1 = Start of the signal triggered by light barrier sensing
2 = Start of the signal when the drive stops at the seam
end
3 = Start from light barrier covered onwards at the
beginning of the seam
4 = Signal A1 only manually switchable
303 do1 Delay of signal A1 2 0 1 A/A/A/A
0 = No delay until signal On
1 = Delay over time until signal On
2 = Delay over stitches until signal On
304 dt1 Delay time until signal A1 On ms 2550 **) 0 0 A/A/A/A
305 St1 ON period of signal A1 ms 2550 **) 0 0 A/A/A/A
306 nA1 Speed mode when signal A1 is On 2 0 0 A/A/A/A
0 = Pedal controlled speed
1 = Limited speed n9
2 = Limited speed n11
307 A1 Signal A1 On/Off 1 0 0 A/A/A/A
308 dA1 Stitches delaying signal A1 stitches 999 0 0 A/A/A/A
309 cA1 Stitch counting during signal A1 stitches 999 0 0 A/A/A/A
310 AA2 Selectable power transistors for signal A2 12 0 0 A/A/A/A
0 = No function
1 = Signal on output M1
2 = Signal on output M2
3 = Signal on output M3
4 = Signal on output M4
5 = Signal on output M5
6 = Signal on output M6
7 = Signal on output M7
8 = Signal on output M8
9 = Signal on output M9
10 = Signal on output M10
11 = Signal on output M11
12 = Signal on output VR
311 So2 Issue signal A2 4 0 0 F/F/F/E
0 = Signal until seam end (according to setting of
parameter 320)
1 = Signal over time
2 = Signal until seam end and drive stops
3 = Signal during stitch counting (according to setting
of parameter 319)
4 = Signal A2 as puller function
312 tr2 Starting point for signal A2 4 0 0 A/A/A/A
0 = Start at the beginning of the seam
1 = Start of the signal triggered by light barrier sensing
2 = Start of the signal when the drive stops at the seam
end
3 = Start from light barrier covered onwards at the
beginning of the seam
4 = Signal A2 only manually switchable
313 do2 Delay of signal A2 2 0 1 A/A/A/A
0 = No delay until signal On
1 = Delay over time until signal On
2 = Delay over stitches until signal On
314 dt2 Delay time until signal A2 On ms 2550 **) 0 0 A/A/A/A
315 St2 ON period of signal A2 ms 2550 **) 0 0 A/A/A/A
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.