EFKA AB220A511171
Supplier Level
Code no. 311 with control operation
Code no. 3112 with control panel operation
Parameter Designation Unit max min Preset Ind.
270 PGm Connection of a sensor e. g. light barrier sensor to 5 0 0 *) A
light barrier socket B18/7. Selection of the desired
function!
0 =The positions are generated by means of the
transmitter incorporated in the motor and can be set
by means of parameter 171.
1 =Setting the sensor to position 2.
Set position 1 using parameter 271, starting from
leading edge position 2.
2 =Setting the sensor to position 2.
Set position 1 using parameter 271, starting from
trailing edge position 2.
3 =Setting the sensor to position 1.
Set position 2 using parameter 271, starting from
leading edge position 1.
4 =Setting the sensor to position 1.
Set position 2 using parameter 271, starting from
trailing edge position 1.
5 =No position sensor available. The drive stops
unpositioned. The thread trimmer function is
suppressed with this setting.
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
= 0V
OUT
OUT
OUT
OUT
ST2
IN
POS1
ST2/20
POS2
ST2/20
POS1
ST2/21
POS2
ST2/21
POS1
ST2/21
ST2/20
POS2
ST2/20
POS1
POS2
ST2/21
POS
B18/7
SEN
= high
0256/SEN-1
Pa 271
Pa 271
Pa 271
Pa 271
360°
270 = 1270 = 3270 = 4 270 = 2
+5V
0V