EFKA AB220A511159
7.2 Operator Level
The preset values of the following list of parameters refer to the setting of parameter 290 = 0.
Parameter Designation Unit max min Preset Ind.
000 c2 - Number of stitches of start backtack forward stitches 254 0 2 *) A
- Number of stitches of start stitch condensing
without stitch regulator
- Number of stitches of end counting “chain
001 c1 - Number of stitches of start backtack backward stitches 254 0 4 *) A
- Number of stitches of start stitch condensing
with stitch regulator
- Number of stitches of start counting “chain
002 c3 - Number of stitches of end backtack backward stitches 254 0 2 *) A
- Number of stitches of end stitch condensing
with stitch regulator
- Number of stitches of tape cutter at the start
of the seam
003 c4 - Number of stitches of end backtack forward stitches 254 0 2 *) A
- Number of stitches of end stitch condensing
without stitch regulator
- Number of stitches of tape cutter at the seam
end
004 LS Light barrier compensating stitches stitches 254 0 7 *) A
005 LSF Number of stitches of the light barrier filter for stitches 254 0 1 A
knitted fabrics
006 LSn Number of light barrier seams 15 1 1 *) A
007 Stc Number of stitches for the seam with stitch stitches 254 0 20 A
counting
008 -F- A parameter from the technician level is assigned to 5 1 1 *) A
the 9 key on the V820 control panel
1 = Softstart On/Off
2 = Ornamental backtack On/Off
3 = Sewing start blocked with light barrier uncovered
On/Off
4 = Unlocking the chain On/Off
5 = Signals A1 and/or A2 On/Off with slide-in strips
1...4 (lefthand arrow = A1, righthand arrow = A2)
009 LS Light barrier On/Off 1 0 0 *) A
013 FA Thread trimmer On/Off 1 0 1 *) A
014 FW Thread wiper On/Off 1 0 1 *) A
015 StS Stitch counting On/Off 1 0 0 A
018 UoS 0 = Sequence “overlock mode with stop” 3 0 0 A
1 = Sequence “overlock mode without automatic
stop. When the command “run” is given, the
drive runs at the preselected speed. With
pedal in pos. 0 or light barrier covered, the
program switches to the next start of a seam
without issuing signals M1/M2.
2 = As with setting “1”. But with pedal in pos. 0
signals M1/M2 will be issued, and the program
switches to the next start of a seam.
3 = As with setting “1”. But with pedal in pos. -2
signals M1/M2 will be issued, and the program
switches to the next start of a seam. Inter-
mediate stop and sewing foot lift with pedal
in pos. –1 are possible.
*) Depending on the selected mode. See table at the beginning of the List of Parameters!