EFKA AB220A511169
Supplier Level
Code no. 311 with control operation
Code no. 3112 with control panel operation
Parameter Designation Unit max min Preset Ind.
240 in1 29 = “Hemmer foot” signal Off (see parameter 296),
function effective only in the seam
30 = High lift for walking foot, if sewing foot is On
31 = Function “speed limitation bit0” (speed n11)
32 = Function “speed limitation bit1” (speed n10)
(bit0 + bit1 = speed n9).
33 = Speed n9 pedal controlled
34 = Automatic speed n9 can be suspended by
pressing the pedal to pos. 0 (neutral)
35 = Automatic speed n9 can be interrupted by
pressing the pedal to pos. -2
36 = Automatic speed n9 without pedal
37 = Speed n12 pedal controlled (break contact)
38 = Automatic speed n12 without pedal
(break contact [N.C.])
39 = Switch to the next pattern in TEACH IN
40 = Switch back to the previous pattern in TEACH IN
41 = Tape cutting only at machine standstill
42 = Enable hot thread chain cutting or sewing foot
lifting. Function effective only in the chain stitch
mode.
43..47 = No function
241 in2 Selection of input function on socket ST2/11 47 0 0 *) A
for input 2
0 = No function
All other functions of the keys as with parameter 240
242 in3 Selection of input function on socket ST2/6 47 0 0 *) A
for input 3
0 = No function
All other functions of the keys as with parameter 240
243 in4 Selection of input function on socket ST2/8 47 0 0 *) A
for input 4
0 = No function
All other functions of the keys as with parameter 240
244 in5 Selection of input function on socket ST2/5 47 0 0 *) A
for input 5
0 = No function
All other functions of the keys as with parameter 240
245 in6 Selection of input function on socket ST2/12 47 0 0 *) A
for input 6
0 = No function
All other functions of the keys as with parameter 240
246 in7 Selection of input function on socket ST2/9 47 0 0 *) A
for input 7
0 = No function
All other functions of the keys as with parameter 240
247 in8 Selection of input function on socket ST2/10 47 0 0 *) A
for input 8
0 = No function
All other functions of the keys as with parameter 240
248 in9 Selection of input function on socket ST2/13 47 0 0 *) A
for input 9
0 = No function
All other functions of the keys as with parameter 240
249 i10 Selection of input function on socket ST2/14 47 0 0 *) A
for input 10
0 = No function
All other functions of the keys as with parameter 240
*) Depending on the selected mode. See table at the beginning of the List of Parameters!