Parameter Designation Unit max min Preset Ind.
150 t8 Stitch correction of the double start backtack ms 500 0 0 A
(prolongation of the stitch regulator ON period /
not effective with ornamental backtack)
151 t9 Stitch correction of the double end backtack ms 500 0 0 A
(prolongation of the stitch regulator ON period /
not effective with ornamental backtack)
152 thP Run-out time of the high lift walking speed ms 500 80 150 *) A
153 brt Braking power at machine standstill 50 0 10 *) A
155 LSG Mode signal “run” 4 0 1 A
0 = Signal Off.
1 = Signal “run” On.
2 = Signal “run” enabled when the speed is >3000 RPM.
3 = Signal with pedal <> 0.
4 = Signal enabled only after motor synchronization
(one rotation at positioning speed after power On)
156 t05 Switch-off delay for the signal “run” or ms 2550 **) 0 0 A
signal with pedal in pos. 0 (neutral)
157 SFS Stitches until thread tension release Off after stitches 254 0 0 A
light barrier covered at the start of the seam
(effective only in overlock mode)
158 dnL Delay time until light barrier speed release ms 500 0 0 *) A
159 cb2 Stitches after light barrier uncovered until stitches 254 0 10 A
signal M9 “hemming blow 2“ Off
161 drE Direction of motor rotation 1 0 1 *) A
0 = Clockwise rotation
1 = Counterclockwise rotation
170 Sr1 Setting the reference position:
- Press the E key.
- Press the >> key.
- Turn handwheel until symbol on display goes off.
Then set the handwheel to the reference position.
- Press the P key twice.
171 Sr2 Setting the needle positions:
1E = Start position 1 degrees 359 0 56 A
2E = Start position 2 281 A
1A = End position 1 98 A
2A = End position 2 323 A
172 Sr3 Display on the control:
Pos. 1 to 1A (LED 7 lights up)
Pos. 2 to 2A (LED 8 lights up)
172 Sr3 Display on the V810 control panel:
Pos. 1 to 1A (lefthand arrow above the 4 key On)
Pos. 2 to 2A (righthand arrow above the 4 key On)
172 Sr3 Display on the V820 control panel:
Pos. 1 to 1A (lefthand arrow above the 7 key On)
Pos. 2 to 2A (righthand arrow above the 7 key On)
*) Depending on the selected mode. See table at the beginning of the List of Parameters!