Parameter Designation Unit max min Preset Ind.
237 tkS Switch-off delay for chain suction at the ms 2550 **) 0 0 A
seam end, if parameter 022 = 2.
238 EnP Software debouncing for all inputs: 1 0 1 A
0 = No debouncing
1 = With debouncing
239 FEL Selection of the input function on socket B18/5 47 0 0 A
0 = Light barrier function, if 009 = 1
All other functions as with parameter 240.
240 in1 Selection of the input functions on socket ST2/7 47 0 0 *) A
for input 1
0 = No function
1 = Needle up/down
2 = Needle up
3 = Single stitch (basting stitch)
4 = Full stitch
5 = Needle to position 2
6 = Machine run blockage effective with open
contact
7 = Machine run blockage effective with closed
contact
8 = Machine run blockage unpositioned effective
with open contact
9 = Machine run blockage unpositioned effective
with closed contact
10 = Automatic speed n12 without pedal
11 = Limited speed n12 pedal controlled
(see parameter 266)
12 = Sewing foot lifting with pedal in position 0
(neutral)
13 = High lift for walking foot with speed limitation n10
(operational mode not stored)
14 = High lift for walking foot (flip-flop 1) with speed
limitation n10
15 = Tape cutter / fast scissors: function only in
chainstitch and overlock mode
16 = Intermediate backtack / intermediate stitch
condensing
17 = Stitch regulator suppression / recall
18 = Unlocking the chain: can be activated by
keystroke, but will be executed only at the
seam end
19 = Reset bobbin thread monitor if parameter
030 = >0
20 = Handwheel running in the direction of rotation
according to the setting of parameter 161
21 = Handwheel running in the opposite direction of
rotation according to the setting of parameter
161
22 = Speed limitation n11 (flip-flop 2). Output
ST2/29 is enabled according to setting of
parameter 186
23 = No function
24 = No function
25 = Speed limitation with ext. potentiometer
On/Off (see parameter 126)
26 = Manual stacker
27 = Unlocking the chain, function is performed
upon pressing the key
28 = External light barrier (according to the
setting of parameter 131)
*) Depending on the selected mode. See table at the beginning of the List of Parameters!