EFKA AB220A5111
60
Operator Level
Parameter Designation Unit max min Preset Ind.
019 -Pd 0 = Pedal in pos. –1 disabled in the seam. With pedal in 4 0 3 *) A
pos. –2 in the seam, only sewing foot lifting is
possible. (Function only if parameter 009 = 1)
1 = Pedal in pos. –1, sewing foot lifting disabled in the
seam.
2 = Pedal in pos. –2, thread trimming disabled.
(Function only if parameter 009 = 1)
3 = Pedal in pos. –1 and –2 enabled in the seam.
4 = Pedal in pos. –1 and –2 blocked in the seam.
(Function only if parameter 009 = 1)
020 kLM Clamp at the seam end On/Off 1 0 0 A
021 ckL Run-out stitches clamp at the start of the seam stitches 254 0 2 *) A
022 SPo 0 = Chain suction until the end of count c2 2 0 0 A
1 = Chain suction at the seam end until pedal in
pos. 0 (neutral)
2 = Chain suction until the drive is at standstill
and the switch-off delay (parameter 237) has
elapsed
023 AFL Automatic sewing foot lifting with pedal forward 1 0 1 E
at the seam end, if light barrier or stitch counting is On
0 = Automatic sewing foot Off
1 = Automatic sewing foot On
025 tFS Start counting (pa. 157) for thread tension release 1 0 1 A
at the start of the seam
0 = Start counting at the start of the seam
1 = Start counting when the light barrier is covered
030 rFw 0 = Bobbin thread monitor Off 6 0 0 A
1 = Bobbin thread monitor with stop
2 = Bobbin thread monitor without stop
3 = Bobbin thread monitor with stop and start
blockage after thread trimming
4 = As 1, but display of remaining stitches
5 = As 2, but display of remaining stitches
6 = As 3, but display of remaining stitches
031 cFw Number of stitches for bobbin thread monitor stitches 25500 ***) 0 0 A
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
***) When programming the 5-digit (max) parameter values on the control or control panel, the 3-digit value displayed
must be multiplied by 100.