EFKA AB220A5111
Technician Level
Code no. 190 with control operation
Code no. 1907 with control panel operation
Parameter Designation Unit max min Preset Ind.
173 Sr4 Checking of the signal outputs and inputs using the
incorporated control panel or the V810/V820 control
panels
01 = Backtacking on socket ST2/34
02 = Sewing foot lift on socket ST2/35
03 = Output M1 on socket ST2/37
04 = Output M3 on socket ST2/27
05 = Output M2 on socket ST2/28
06 = Output M4 on socket ST2/36
07 = Output M5 on socket ST2/32
08 = Output M11 on socket ST2/31
09 = Output M6 on socket ST2/30
10 = Output M9 on socket ST2/25
11 = Output M8 on socket ST2/24
12 = Output M7 on socket ST2/23
13 = Output M10 on socket ST2/29
OFF/ON = By actuating the switches connected to the
control, the function of these switches is
checked and displayed on the control.
OFF is displayed with open switch and the
activated input in1...i10 with closed switch.
179 Sr5 Control program number with index and identification
number. Upon pressing the appropriate key the data
will be displayed in succession.
V810 control panel display example:
Press the E key è Display e. g. Sr [°]
Press the >> key è Display e. g. 5111A
Press the E key è Display e. g. 010823
Press the E key è Display e. g. 15
Press the P key twiceè Display Ab220A
V820 control panel display example:
Press the E key è Display F-179 Sr5 [°]
Press the >> key è Display e. g. 5111A
Press the E key è Display e. g. 01082315
Press the P key twiceè Display 4000 Ab220A
See instruction manual for control display example.
180 rd Number of reversing increments degrees 359 0 175 *) A
181 drd Switch-on delay of reverse motor rotation ms 990 0 10 *) A
182 Frd Reverse motor rotation On/Off 1 0 0 *) A
183 FFm Disabling of flip-flop functions at the seam end 3 0 0 A
0 = Flip-flop 1 (M6) and flip-flop 2 (M10) not disabled
at the seam end
1 = Flip-flop 1 (M6) disabled at the seam end
2 = Flip-flop 2 (M10) disabled at the seam end
3 = Flip-flop 1 (M6) and flip-flop 2 (M10) disabled
at the seam end
184 c6 Number of run-out stitches when unlocking the stitches 254 0 20 *) A
chain
185 chP Stitch counting high lift for walking foot stitches 254 0 0 A
186 FFi Function “speed limitation n11” 1 0 0 *) A
0 = Speed limitation n11 On, when signal M10 is On.
Speed limitation n11 Off, when signal M10 is Off.
1 = Speed limitation n11 Off, when signal M10 is On.
Speed limitation n11 On, when signal M10 is Off.
187 FFo Function of signal M10 after “power On” (flip-flop 2) 1 0 0 *) A
on socket ST2/29
0 = Signal M10 Off / speed limitation n11
according to setting of parameter 186
1 = Signal M10 On / speed limitation n11
according to setting of parameter 186
*) Depending on the selected mode. See table at the beginning of the List of Parameters!